Railway Cables | ||||||||||
|
K209B LSZH Armoured Optical Fiber Cables
Application
The cables are designed for long distance telecommunication and using optical fibres in urban railways
infrastructure. These low smoke halogen-free cables are laid on hooks, pulled through ducts or cable trays.
Standards
RATP K209B or RATP K209A
Construction
Compact Tube
6 or 12 singlemode optical fibres G652 or multimode fi bers assembled under thermoplastic “peelable” skin. Tube
diameter: 1mm.
Filling
Water-swelling yarns.
Tube
Thermoplastic.
Peripheral Strength Member
Water-swelling glass yarns.
Armour
Corrugated steel tape armour 25/100.
Sheath
LSZH.
Optional
K209A Type: For K209A type, the cables have loose tubes with 6-12 fi bers, steel wire strand as central strength
member, glass yarn reinforced, incorporating a corrugated steel tape armour and an outer UV stabilized LSZH
jacket.
Electrical Characteristics at 20℃
Optical & Geometrical Properties for Single Mode Fibers
Maximum Attenuation | G652 | |
@1310nm | dB/km | 0.35 |
@1550nm | dB/km | 0.22 |
Maximum Chromatic Dispersion | ||
Between 1260 and 1360nm | ps/(nm/km) | 3.5 |
Between 1530 and 1565nm | ps/(nm/km) | 19 |
Zero Dispersion Wavelength | nm | 1310±11 |
Zero Dispersion Slope | ps/(nm2.km) | 0.09 |
Numerical Aperture | 0.14 | |
Point discontinuity | dB | 0.1 |
PMD (individual fi ber) | ps/km | 0.2 |
Maximum Cutoff Wavelength | nm | 1260 |
Cladding Diameter | um | 125±1 |
Core/Cladding Concentricity Error | um | ≤0.5 |
Cladding Non Circularity | % | ≤1 |
Coating Non Circularity | % | ≤6 |
Proof Test Level | Kpsi (GN/m2) | 100 (0.7) |
Crush Resistance | N/cm | 300 |
Maximum Laying Tension | N | 3000 |
Optical & Geometrical Properties for Multimode Fibers
50/125 | 62.5/125 | ||
Maximum Attenuation | |||
@850nm | dB/km | ≤2.5 | ≤3.0 |
@1300nm | dB/km | ≤0.7 | ≤0.8 |
Maximum Chromatic Dispersion | |||
@850nm | MHz*km | ≥500 | ≥200 |
@1300nm | MHz*km | ≥800 | ≥500 |
Zero Dispersion Wavelength | nm | 1310 | 1310 |
Numerical Aperture | - | 0.20±0.015 | 0.275±0.015 |
Core Diameter | um | 50±3 | 62.5±3 |
Cladding Diameter | um | 125±2 | 125±2 |
Core/Cladding Concentricity Error(Offset) | um | ≤1.5 | ≤1.5 |
Coating-Clad Concentricity Error(Offset) | um | ≤8 | ≤8 |
Core Non-Circularity | % | ≤6 | ≤6 |
Cladding Non-Circularity | % | ≤2 1 | ≤2 1 |
Coating Diameter | um | 245±10 | 245±10 |
Proof-Test Level | Kpsi (GN/m2) | 100 (0.7) | 100 (0.7) |
Mechanical and Thermal Properties
Minimum Bending Radius:20×OD
Temperature Range: -40℃ to +60℃ (during operation);
-10℃ +60℃ (during installation)
Dimensions And Weight
K209A
Cable Code | No. of fibres |
Distribution | Nominal Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
RO/K209A-ML-C-9-TnxFn-SR-(STA)H | 1-36 | 6 fi bre per tubes | 1.8 | 12 | 190 |
RO/K209A-ML-C-9-TnxFn-SR-(STA)H | 42-72 | 6/12 fi bre per tubes | 1.8 | 13.5 | 230 |
Tn: Number of tubes; Fn: Number of fi bers in a tube
K209B
Cable Code | No. of fibres |
No of Tubes x No of Fibers/Tube |
Nominal Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
Singlemode Fibres From 6 to 36 OF – G652 | |||||
RO/K209B-ML-C-9-2x6-F-(STA)H | 12 | 2 tubes of 6 OF | 1.8 | 13 | 112 |
RO/K209B-ML-C-9-4x6-F-(STA)H | 24 | 4 tubes of 6 OF | 1.8 | 13 | 112 |
RO/K209B-ML-C-9-6x6-F-(STA)H | 36 | 6 tubes of 6 OF | 1.8 | 13 | 112 |
Singlemode Fibres From 48 to 72 OF – G652 | |||||
RO/K209B-ML-C-9-8x6-F-(STA)H | 48 | 8 tubes of 6 OF | 2.5 | 15.5 | 230 |
RO/K209B-ML-C-9-6x12-F-(STA)H | 72 | 6 tubes of 12 OF | 2.8 | 15.5 | 230 |
Multimode Fibres From 6 to 36 OF – 50/125 | |||||
RO/K209B-ML-C-9-1x6-F-(STA)H | 6 | 1 tubes of 6 OF | 1.8 | 13 | 112 |
RO/K209B-ML-C-9-2x6-F-(STA)H | 12 | 2 tubes of 6 OF | 1.8 | 13 | 112 |